According to the National Council on Radiation Protection and Measurements (NCRP), the monthly gestational dose-equivalent limit or embryo/ Fetus of a pregnant radiographer is
A.

0.1 mSv

B.

0.5 mSv

C.

1.0 mSv

D.

5.0 mSv

Show Answer

Correct Answer � B

Explanation

Ans. (B)

The pregnant radiographer poses a special radiation protection consideration, or the safety of the unborn individual. It must be remembered that the developing fetus is particularly sensitive to radiation exposure. Therefore, established guidelines state that the occupational gestational dose-equivalent limit or embryo/ fetus o a pregnant radiographer is 5 mSv (500 mrem), not to exceed 0.5 mSv in 1 month. According to the NCRP, the annual occupational whole-body dose-equivalent limit is 50 mSv (5 rem or 5,000 mrem). The annual occupational whole-body dose-equivalent limit or students under the age o 18 years is 1 mSv (100 mrem or 0.1 rem). The annual occupational dose-equivalent limit or the lens of eye is 150 mSv (15 rem). The annual occupational dose-equivalent limit or the thyroid, skin, and extremities is 500 mSv (50 rem).