Moist Heat Sterilization

Moist Heat Sterilization


Mechanism of Action

  • Denaturation and coagulation of proteins
Temperature below 100oC:

  • For pasteurization of milk
  • Holder method
    • 65oC for 30 min
  • Flash Process
    • 72oC for 15 sec
  • Pasteurization kills nearly 90% of the bacteria in milk
  • Including the more heat resistant – Tubercle bacilli
  • It does not kill bacterial spores.
  • It does not kill the thermoduric bacteria.

Also used for :

  • Vaccines of nonsporing bacteria
  • Serum or body fluids containing coagulable proteins.

Methylene blue Reduction test:Pasteurization of milk is determined by:

  • Indirect test 
  • Detection of microorganism in milk.
  • Prior to the process of pasterurization
  1. Phosphatase testColiform count
    • Alkaline Phosphatase (ALP) is an enzyme naturally present in all raw milk
    • Used as an indicator of proper milk pasteurization.
    •  Complete pasteurization will inactivate the enzyme .
  2. Standard plate count

Temperature at 100oC (Boiling):

  • Rolling boil
  • boiling for 5-10 minutes
  • Kill bacteria, but not spores or viruses

Steam at Atmospheric Pressure 1000C:

  • Koch or Arnold steamer is usually used the container
  • Culture media are simultaneously sterilized.
  • A single exposure of 20 min usually ensures sterilization
  • Tyndallization
    • An exposure of 100oC for 20 minutes
    • For three successive days 
Steam under pressure /Autoclave/steam sterilizer (>100oC)

  • Most effective sterilizing agent for
    • dressing
    • instruments
    • laboratory wares
    • media and pharmaceutical products
    • aqueous solutions.
  • Not for sharp instruments

Done at:

  • Temperature of 121oC
    • keeping chamber pressure of 15lb per square inch
    • For 15 min.
  • 126o
    • 20lbs psi
    • for 10 min
  • on 133o
    • 30 lbs psi
    • for 3 min.

Biological indicators

  • Spores of Bacillus stereothermophilus (Geobacillus stearothermophilus) are used.
  • Spores of Bacillus subtilis and Bacillus pumilis are also used.

Exam Important

Temperature below 100oC:

  • For pasteurization of milk
  • Holder method
    • 65oC for 30 min
  • Flash ProcessPasteurization kills nearly 90% of the bacteria in milk 
    • 72oC for 15 sec 
  • Including the more heat resistant – Tubercle bacilli 
  • It does not kill bacterial spores. 
  • It does not kill the thermoduric bacteria. 

Pasteurization of milk is determined by:

  1. Phosphatase testColiform count
    • Alkaline Phosphatase (ALP) is an enzyme naturally present in all raw milk
    • Used as an indicator of proper milk pasteurization.
    •  Complete pasteurization will inactivate the enzyme .
  2. Standard plate count

Steam under pressure /Autoclave/steam sterilizer (>100oC)

  • Most effective sterilizing agent for
    • dressing
    • instruments
    • laboratory wares
    • media and pharmaceutical products
    • aqueous solutions.
  • Not for sharp instruments

Done at:

  •  Temperature of 121oC
    • keeping chamber pressure of 15lb per square inch
    • For 15 min.
  • 126o
    • 20lbs psi
    • for 10 min
  • on 133o
    • 30 lbs psi
    • for 3 min.

Biological indicators

  • Spores of Bacillus stereothermophilus (Geobacillus stearothermophilus) are used.
  • Spores of Bacillus subtilis and Bacillus pumilis are also used.
Don’t Forget to Solve all the previous Year Question asked on Moist Heat Sterilization
Click Here to Start Quiz