Radiation

Radiation


Radiation

  1. Bremsstrahlung radiation (General radiation) : – Bremsstrahlung x-rays are produced when energetic electron interact with nuclear electric field in target. When an electron passes near the nucleus of tungston atom of target (anode), the positive charge of nucleus attracts the negatively charge electron. Electron is thus deflected from its original direction and it may lose energy as it is slowed down when its direction changes. The kinetic energy lost by the electron is emitted directly in the form of photon of radiation (x-rays). Most x-rays produced in radiographic (plane x-ray), fluoroscopic, and CT imaging are via Bremsstrahlung processes.
  2. Characteristic radiation : – Characteristic radiation results when energetic electron causes ejection of the electron from the inner orbit of target atom. The resultant vacancy is filled by an outer shell electron and the energy difference is emitted as x-ray (photon). Only K-shell (AMU“characteristic x-ray are important in diagnostic radiology. 
  • These photon x-rays (Produced by x-ray tube) are than transmitted through the body to produce image on x-ray film (in plane x-ray) or an CT plates (in CT scan).
  • So, order of sequence in x-rays imaging is 
  • Movement of 4 Electrons hit Emmision Transmission -› Image on electrons the target ofphoton through the x-ray film towards Target (anode) (anode) (x-ray) body of CT plate ” v:shapes=”_x0000_s1036″> 

Exposure factors

  • Two exposure factors are important
  1. Kilovolt peak (KVP(DNB 15))-It is the voltage which is applied between filament (cathode) and target (anode). It creates an electrical potential between the anode and cathode so the electron from the cathode travel to the anode. It provides kinetic energy to x-ray, therefore it is responsible for penetrating power of x-rays, higher the KVP more the penetrating power of x-rays. Contrast is also influenced by KVP (Assam 95),lower the KVP higher the contrast (contrast is the difference in optical densities in the various regions of x-ray film which allows for differentiation of anatomic structures).
  2. Milliampere second (mAs) : – It is the combination of electric current for heat production at cathode. It determines the number of x-ray photons. It controls the density of the film, i.e., amount of blackening of film (Density refers to overall blackening of the film).

Radiography (Plane-x-ray)

  • You should keep in mind the basic fact that x-rays causes blackening of the x-ray film, if it strikes directly. When they are transmitted through the body, absorption of x-rays occurs and depending on the amount of absorption different shades are produced. For example, bones absorp maximum x-ray and produce white shadow; muscles and soft tissue (except fat) absorb less than bone and produce grey image; fat absorbs slightly fewer x-rays and therefore appears a little blacker than outer soft tissues; and air absorbs the least x-rays and therefore cause maximum blackening.
  • So, image on x-ray film is produced by attenuation of x-rays which is the reduction of the intensity of an x-ray beam as it traverses through the body. The substance which causes maximum attenuation (like bone) produces more white image, on the other hand air/gas produces black image as it causes minimal attenuationo)NB-‘0.

 Effects on patients built on radiographic images

  • Radiographic images are affected by the build of patient. There are four body types.
  1. Sthenic : – This is considered the average body build. This body type is the basis for established exposure factors (KVP and mAs).
  2. Hypersthenic : – The patient has heavy body build. The body requires more exposure factors (KVP and mAs) (MO2) _
  3. More mAs : – Because thicker objects absorp more x-ray photons; by increasing mAs, number of photon is increased.
  4. More KVP : – Thicker objects produces more resistance, it can be penetrated by increasing the KVP which increase the penetrating power of x-rays.
  5. Hyposthenic : – Patient is healthy but some what underweight for height, i.e., thin but healthy. These patient’s require less exposure factors (mAs & KVP) than those with a sthenic body.
  6. Asthenic : – The patient is ill and emaciated. This body type requires the least amount of exposure factors (mAs & KVP).
  • Quantity of exposure is directly proportional to (kVp)2. Thus reducing kVp by 50% would reduce the radiation dose to 25% (i.e. 75% reduction in radiation dose)

(kVp)2 x mAs x Z uantity of X-ray —d2

Interactions of x-rays and matter

  • When photon (x-ray), passes through a matter (e.g., human body it interacts with atoms of that matter). Following type of interaction occurs (only first two are important in diagnostic radiology) : ?

1. Compton scattering

  • It is the most common(“13) type of interaction in diagnostic radiology and is responsible for most scattered radiation. Compton scattering occurs when the an x-ray photon interacts with an electron in outer orbital shell of an atom and gives part of its energy (IiPmer th5) to outer shell electron. The outer shell electron (compton electron) is ejected out from the atom and results in ionization of the atom. As a result of the interaction, the x-ray photon is redirected (scattered) with decreased energy and a longer wavelength. The probability of compton scattering is proportional to the outer-shell electrons available in the medium. H+ ion does not have any electron, therefore it cannot cause scattering

(AI 97, 96, Delhi 96).

2. Photoelectric absorption

  • It is the second most common interactions. Photoelectric absorption occurs when x-ray photon gives up all its energy to inner shell electron 02“of an atom. When this occurs, the inner shell electron (photoelectron) is ejected from the inner shell leaving a vacancy to be filled in the shell. This vacancy is filled with an outer shell electron and the energy defference is emitted as characteristic radiation.
  • Photoelectric absorption is the same as occur in the production of x-ray by characteristic radiation in target (anode) of x-ray tube. However, photoelectric absorption occurs in the matter through which x-ray photons are transmitted e.g., human body. Therefore photoelectric absorption increases the radiation exposure : – i) The patient is already exposed to x-ray photon, and ii) Also exposed to characteristic radiation produced within the body by photoelectric interaction.

3. Coherent scatter (classical or thompson’s scattering)

  • This is not important in diagnositc radiology. Coherent scatter occurs when a low energy photon excites an atom but then passes through without any electron ejection from atom. Electron are not removed but vibrate due to deposit of energy from the photon. As the electrons vibrate, they releases this extra energy as ascattered x-ray photon having energy equal to the energy of the original photon (i.e., low energy)

4. Photodisintegration

  • A very high energy x-ray photon strikes the atomic nucleus, causing a nuclear fragment to eject. This does not occur in diagnostic radiology.

5. Pair production

  • It involves an interaction between the x-ray photon and nucleus. The impact of the interaction causes the incoming x-ray photon to disappear and in its place two electrons appear. This does not occur in diagnostic radiology.
  • Low energy phenomenon → Photoelectric effect, ou“)Coherent scatter
  • Mid energy phenomenon → Compton scattering
  • High energy phenomenon → Pair production

Important facts about x-ray radiography

  • Filament (cathode) and Target (anode) are made of Tungsten (AMU 90, PGI 83) However, In mammography the target (anode) is made of Molybdenum (“”MS 89) or rhodium.
  • Anode of the x-ray tube can either be stationary or rotating. Most of the modern x-ray tubes have rotating anode because rotating anode have better heat dissipiation. The x-ray tube uses all three forms of cooling i.e., radiation, conduction and convection. However, radiation is most important
  • X-ray grid (Punjab 11, WB 98) is the part of x-ray machine that ensures the clarity of image on x-ray film. Scattered x-rays, when hit the film can cause blurring of image. X-ray grid absorbs scattered x-rays (WB 98‘ P””jab Wand filters out radiations.
  • Filter is the device which absorbs low energy photons (“P 93) and there by decreases the radiation exposure to the patient. When x-rays passes through the body, low energy photons are not able to penetrate, and are absorbed or scattered. Therefore, these low energy photons do not produce any image but expose the patient to radiation. Filter of the x-ray machine absorbs these low energy photon and decreases radiation exposure. Filter is usually made of aluminium or aluminium copper combination.
  • Window is the part of x-ray machine through which the x-ray beam is emitted towards the patient.
  • Collimators are used to restrict the size of the x-ray beam, i.e., restriction of field size. In simple words, collimators eliminate peripheral (more divergent) portion of x-ray beam. As peripheral part of beam contains scatter radiation (along with normal radiation), collimator also decreases scatter radiation.
  • X-ray film is photographic film, coated on both side of a polyester film base, i.e., double emulsion film (single emulsion film is coated on one side). The photosensitive material (which produces image on exposure to light) is silver halide (90-99% of silver bromide (DPG 1“)and 1-10% of silver iodide) (BM 92) As x-ray film has relatively poor sensitivity to x-rays, intensifier screens are used to convert the x-ray energy to light energy. When film is exposed to this light energy (from intensifier screen), light causes the grains of silver halide to form a ‘latent (invisible) image: This image is developed in a developer (Hydroquinone + metol/ phenindione) which creats visible image. After the image has been developed, the resultant image is then fixed by a fixer (Hypo-sodium thiosulphate) which removes unused silver halide, which would make the film appear milky or cloudy. X-ray film should be developed in dark room, otherwise light will spoil the film (x-ray film has photosensitive silver bromide). Blue and green light are most sensitive whereas yellow and red light are

 least (Rajasthan 93).

  • Film focus distance (the distance from x-ray tube target, i.e., anode to the x-ray film) is 100 cms (40 inches) for routine radiography. While for chest x-ray it is 180 cm (72 inches or 6 feet) to reduce magnification (TN 92) as short distance increases the magnification of body part.
Exam Question
 
  • Back ground radiation is a low level, wide spread (ubiquitous), constantly present radiation from natural sources that is usually not detrimental to life.
  • About Electromagnetic radiation: Infrared is a EM radiation , Compton scattering occur for intemediate energy.
  • Amount of radiation delivered to an organ is defined as absorbed dose.
  • Equivalent dose is a measure of biological damage caused by the absorbed dose depending on the relative effectiveness of type of radiation; and effective dose is a measure to assess the risk of carcinogenesis & genetic defect by calculating an imaginary total body dose depending on equivalent dose for each organ and relative sensitivity of each organ to radiation.
  • Alpha is the most ionizing radiation.
  • Functional basis of ionising radiation depends on removal of orbital electron.
  • Radiation produces its effect on tissue by charring of nucleoprotein,Denaturation of DNA.
  • Radium emits α rays;  β-rays;  γ -rays.
  • Maximum permissible radiation dose in pregnancy is 0.5 rad.
  • Most common hormone deficiency seen after intracranial radiation therapy is Growth hormone.
  • MC cancer due to Radiation is Leukemia.
  • Mucositis and Enteritis are late effects of radiation therapy.
  • Most common early (acute) manifestation of local skin reaction is erythema which is followed by desquamation.
  • ‘Stochastic effects’ of radiation:Probability of effect is a function of dose.
  • Low dose radiation cause Lung cancer;  AML;  Cervical cancer.
  • Dose of radiation during whole body exposure that leads to haematological syndrome is 2 Gy.
  • USG is based on piezoelectric effect of lead-zirconate titanate and MRI is based on gyromagnetic property of proton (hydrogen nucleus). Both are associated with no risk of radiation exposure.
  • The radiation exposure in decreasing order is CT scan > Barium enema > Dynamic cardiac scan > PET > Bone scan > IVU > Xray.
  • Radiation is an etiological agent for papillary carcinoma thyroid & external radiation is used in treatment of anaplastic cancer thyroid.
  • Total skin electron irradiation is used for Mycoses Fungoides.
  • The source of endogenous radiation is Potassium.
  • Terrestrial radiation is maximum in Kerela.
  • Effect of radiation above threshold level is non-stochastic effect.
  • 0.05 mm is the approximate penetrating ability of alpha particle radiation at tissue level.
  • Unit of one of radiation absorbed is  Gray.
  • The maximum permissible level of occupational exposure to radiation is 5 rad per year.
  •  Testicular tumour most sensitive to radiation is Seminoma.
  • Differentiated thyroid carcinoma particularly papillary variety frequently follows accidental irradiation of thyroid in infancy and childhood.
  • Most common type of cataract following radiation is Posterior Subcapsular.
  • Bone Tumour which can occur following exposure to radiation is Osteosarcoma.
  • Dactinomycin requires a dose adjust­ment in patient during radiotherapy in order to pre­vent radiation toxicity.
  • Radiation of 5 Gy will kill patients in 4-6 weeks.
  • 6-10 Gy radiation dose is needed for permanent testicular sterilization in normal male.
  • Treatment for post-radiation skin lesion like desquamation is observation alone.
  • Malignant Melanoma is least sensitive to radiation.
  • MRI and USG are not using ionising radiation.
  • Least affected by radiation is Cartilage.
  • Mantle irradiation is used in Hodgkin’s Disease.
  • One gray of radiation is equal to 100 rad.
  • Cell most sensitive to radiation is Lymphocyte.
  • Commonly used type of radiation in radiotherapy is Gamma Rays.
  • Radiation protection shields are made up of: Lead.
  • Anaplastic Carcinoma  responds best to radiation.
  • Thickness of lead apron to prevent radiation is 0.5 mm.
  • Acute radiation sickness is characterised by:Hematological symptoms , CNS symptoms , Gastrointestinal symptoms.
  • Least sensitive structure to radiation is Vagina.
  • Intracavitary radiation is given in Carcinoma of Cervix.
  • The most common presentation of radiation carditis is Pericardial Effusion.
  • Features of radiation include Fluorescein , Biological  ,Photographic.
  • The radiation tolerance of whole liver is 40 Gy.
  • 8 Gy in one fraction of radiation therapy is recommended for pain relief in bone metastases.
  • Planned radiation volume is more than targetted radiation volume.
  • 80-85 and 85-90 gy is the maximum radiation dose to point A for early and advanced Ca cervix.
  • SI unit of dose of radiation absorption is BPD.
  • Foam Cells in vessel wall is the characteristic histological finding of chronic radiation pneumonitis.
  • Phase of the Cell cycle which is most sensitive to radiation is G2M.
  • Ionizing radiation commonly used for disinfection is Gamma Rays.
  • Unit of radiation exposure is Roentgen.

Units of potency

  • Roentgen and coulomb per kilograme → Units of exposure. It is the amount to which a person is exposed.
  • Red and Gray→ Units of absorbed dose. It is the amount which is absorbed per gram of tissue.
  • Rem and Sievert → Product of the absorbed dose and the modifying factor. Represent the degree of potention danger to health
Don’t Forget to Solve all the previous Year Question asked on Radiation