CLINICAL MONITORING OF ANESTHESIA
Introduction:
- Clinical monitoring of anesthesia is equal to monitoring neuromuscular block.
- Done by recording contractile responses of specific nerves/target sites.
Sites of monitoring:
- 1st choice –
- Thumb muscle (adductor pollicis) to transcutaneous ulnar nerve stimulation.
- Best site for ulnar nerve stimulation – Volar side of wrist.
- 2nd most common (after ulnar nerve):
- Facial nerve stimulation of orbicularis oculi.
- Orbicularis oculi responses correspond with laryngeal muscles.
Other nerves:
- Median nerve, posterior tibial nerve & common peroneal nerve.
Patterns observed:
- 4 main patterns observed.
- Occurs on application of electric stimuli to specific nerve (ulnar) –> recording evoked response.
1. Twitch:
- Normally there is muscle twitch.
- Single stimulus 0.2 ms duration applied at slow rate.
- Both depolarizing & non-depolarizing blockers cause depression of twitch height.
2. Tetany:
- Sustained stimulus (tetanic stimuli) of 50 – 100 Hz applied.
- High-frequency stimulus cause summation of individual stimuli – Tetanic contraction occurs.
- Non-depolarizing blocker causes successive decrease/progressive fade (fade phenomenon) in evoked response.
- Also, shows post-tetanic potentiation.
- Depolarizing blockers (Sch) causes constant diminution in response, but no fade phenomenon.
- Do not show post-tetanic potentiation.
Mechanism of fade phenomenon:
- Due to decreasing acetylcholine released from prejunctional membrane with repetitive stimuli.
- Depolarizing blocker (Sch) do not act on pre-junctional nicotinic receptor – Hence do not show fade phenomenon.
Mechanism of post-tetanic potentiation:
- After 1st tetanus –> Non-depolarizing blocker effect on pre-synaptic receptors reduced –> transient Ach level increase –> causing post-tetanic potentiation.
- Depolarizing blocker (Sch) do not block pre-junctional nicotinic receptor – Hence do not show post-tetanic potentiation.
3. Train of four (TO4):
- Most commonly used protocol.
- Four successive 200 μ sec (0.2 sec) stimuli over 2 sec (2 Hz) applied.
- Gap between each stimuli – 0.5 sec.
- In normal person (without neuromuscular block) all 4 evoked responses (contractions) same.
- Non-depolarizing blocker causes successive decrease/progressive fade (fade phenomenon).
- Depolarizing blockers (Sch) cause constant diminution in response (no fade phenomenon).
4. Double – burst stimulation (DBS):
- Non-depolarizing blockers cause successive decrease/progressive fade (fade phenomenon) in evoked response.
- Depolarizing blockers (Sch) cause constant diminution of response.
Exam Important
- Clinical monitoring of anesthesia is done by recording contractile responses in thumb muscle (adductor pollicis) to transcutaneous ulnar nerve stimulation.
- Best site for ulnar nerve stimulation is volar side of wrist.
- 2nd most common location for monitoring of anesthesia is after ulnar nerve is facial nerve stimulation of orbicularis oculi.
- Both depolarizing & non-depolarizing blockers cause depression of twitch height.
- Non-depolarizing blocker causes successive decrease/progressive fade (fade phenomenon) in evoked response & shows post-tetanic potentiation
- Depolarizing blockers (Sch) causes constant diminution in response, but no fade phenomenon & post-tetanic potentiation.
- Fade phenomenon occurs due to decreasing acetylcholine released from prejunctional membrane with repetitive stimuli.
- Depolarizing blocker (Sch) do not act on pre-junctional nicotinic receptor – Hence do not show fade phenomenon.
- Depolarizing blocker (Sch) do not block pre-junctional nicotinic receptor – Hence do not show post-tetanic potentiation.
- Train of four (TO4) is most commonly used protocol for monitoring clinical anesthesia.
- Non-depolarizing blocker causes successive decrease/progressive fade (fade phenomenon) in TO4.
- Depolarizing blockers (Sch) cause constant diminution in response (no fade phenomenon) in TO4.
- In Double – burst stimulation (DBS):
- Non-depolarizing blockers cause successive decrease/progressive fade (fade phenomenon) in evoked response.
- Depolarizing blockers (Sch) cause constant diminution of response.